1. After long-term use of curbstone molds, the cutting edge must be sharpened. After grinding, the cutting edge surface must be demagnetized and cannot be magnetic, otherwise it is easy to cause blockage.
2. During the use of curbstone molds, the punches are prone to breakage, bending and gnawed, and the punch sleeves are generally gnawed. The damaged punches and punch sleeves are generally replaced with parts of the same specifications.
3. When maintaining the curbstone mold, check the accessories of each part and whether there is any damage, repair the damaged parts, check for air leakage by pneumatic ejection, and take measures for specific situations.
4. During the use of curbstone molds, elastic parts such as springs are most easily damaged, usually breaking and deforming. The solution is to replace them. During the replacement process, you must pay attention to the specifications and models of the springs. The specifications and models of the springs are confirmed by color, outer diameter and length. Only when all three items are the same can they be replaced.